water disinfection system
Magnum系统特性
  标准型号规格参数
 

使用紫外线方法对废水进行消毒处理

  建议安装
Magnum ultraviolet open channel water disinfection system

- 35 to 695 gallons per minute, up to 2 million gallons per day
- Stainless Steel construction
- Suspended racks that hold several modules of uv germicidal lamps
- Racks are submerged parallel to the flow in an open channel
- Modules contain between two and eight lamps
- Power Supply and monitoring controls are several feet away
Units are customized to individual application utilizing standard modules


Special Features of the Magnum Water Purifiers

Modular Design: Each system consists of several lamp modules utilizing 2 or 4 ultraviolet germicidal lamps, each contained in a fused quartz sleeve and mounted in a stainless steel frame. Modular design permits a treatment approach tailored to your specific requirements without the need to resort to custom design for each application. Modules can be easily removed or swapped to enable maintenance or service with a minimum of system down time.
Uniform Lamp Spacing: The lamp spacing has been carefully conceived to provide a uniform germicidal dosage throughout the disinfection channel. As a result, Magnum units provide a consistent well-balanced exposure of the effluent.
Low-Pressure Lamps: Similar to mercury arc fluorescent lamps, however they are constructed from quartz envelope rather than a glass envelope and emit over 90 percent of their ultraviolet energy at 253.7 nanometers which is the region of maximum germicidal effectiveness and highly lethal to virus, bacteria and mold. The rated life of Ster-L-Ray germicidal lamps is 10,000 hours and operating wall temperature is about 104 degrees Fahrenheit. The electrical cost of operating a low-pressure lamp is equal to that of a fluorescent lamp of the same size and wattage.
Lamp Operation Indicators (L.E.D.): Pilot lamp array provides individual indication of operation for each germicidal lamp and facilitates quick location of the problem in the event of germicidal lamp outage.
Ultraviolet Monitor: Visually indicates the level of germicidal ultraviolet available after penetration of the quartz sleeve and the liquid medium and can provide data to a remote location.
NEMA 4x Electronic Enclosure: Water tight stainless steel enclosure protects electronic components from outside environment. Quarter turn latches provide ready access to interior components for inspection and lamp replacement.
Elapsed Time Indicator: Provides visual indication (in hours) of the time that the unit is in service and serves as an aid for periodic maintenance.
Electronic Ballast: State-of-the-Art electronic ballasts use significantly less power and operate cooler and more reliably than conventional ballasts.

 
 

-紫外线杀菌灯管简介

-Slimine杀菌灯管

-Slimine U型杀菌灯管

-冷阴极杀菌灯管

-预热型杀菌灯管

-杀菌灯管运行参数

-其它品牌杀菌灯管

-石英套管

-镇流器

-灯插座
-紫外强度监视及报警
-Guardian强度监视器

-灯管状态显示器

-远程灯管状态显示器

 
  北京博朗特科技有限公司
Beijing BrightStars Science and Technology Corp.

自2005年10月7日我公司迁入以下新址:
地址:北京市崇文区广渠门内南小街 领行国际中心3-2-1605
邮编:100061
电话:010-67150266,67150276,67150278,67150279
传真:010-67155606
www.brightstars.com.cn
;网络实名:博朗特 e-mail:info@brightstars.com.cn